R&S?SGT100A SGMA 矢量射頻旌旗燈號源

 提醒:點擊圖片能夠縮小
重要性優點
• 頻率和電平變換情況僅為240 μs(經典故事)的矢量圖旌旗燈號產生了器,使用在生產中不斷進步生產率
• 高達mg6GHz、整合基帶形成器的大中型自力矢量圖旌旗燈號形成器(高1.5HU、寬19厘米)
• 結合有高達hg240 MHzI/Q調變帶寬使用(頻射)的基帶會產生器,撐持不斷進步老員工號碼正確,涉及IEEE 802.11ac
• 精彩絕倫的EVM和ACLRrf射頻性能
• 方便巧用R&S®WinIQSIM2™仿真模型軟文先天自然數管理規范旌旗燈號,如LTE 和LTE-Advanced
• 在采用不少于正反領受定向天線的MIMO采用添加強R&S®SMW200A
Key Facts
  • Fastest vector signal generator with frequency and level switchover times of 240  μs (typ.) for optimized throughput in production
  • Smallest standalone vector signal generator up to 6 GHz with integrated baseband generator (1 HU ½ 19")
  • Integrated baseband generator with I/Q modulation bandwidth of up to 240 MHz (in RF) supporting all advanced digital standards, including IEEE 802.11ac
  • Excellent RF performance for EVM and ACLR
  • Easy signal generation for digital standards such as LTE and LTE-Advanced using the R&S®WinIQSIM2™simulation software
  • Ideal enhancement for the R&S®SMW200A in MIMO applications with more than two receiving antennas
Specifications
 
Frequency
Frequency range CW mode and I/Q mode 1 MHz to 3 GHz
  with the R&S®SGT-KB106 option
CW mode and I/Q mode
 
1 MHz to 6 GHz
Setting time with PCIe/Ethernet remote control < 500 μs
Input frequency for external reference into R&S®SGT100A 10 MHz, 13 MHz, 100 MHz, 1000 MHz
Level
Specified level range   –120 dBm to +17 dBm (PEP)(peak envelope power)
Setting time with PCIe/Ethernet remote control, setting characteristic: auto < 500 μs
Spectral purity
Harmonics level ≤ 8 dBm, CW, I/Q wideband off < –30 dBc
Nonharmonics level > –10 dBm, offset > 10 kHz from carrier, f ≤ 1.5 GHz < –76 dBc
Wideband noise 10 MHz carrier offset,level > 5 dBm, 1 Hz meas. bandwidth, CW < –145 dBc
SSB phase noise 20 kHz carrier offset, 1 Hz measurement bandwidth
  f = 1 GHz < –126 dBc; –133 dBc (typ.)
  f = 6 GHz < –110 dBc; –117 dBc (typ.)
Pulse modulation   optional, with the R&S®SGT-K22 option
On/off ratio   > 80 dB
Minimum pulse width using the integrated pulse generator 20 ns
I/Q modulation
I/Q modulator bandwidth (RF) using an external analog signal
100 MHz < f ≤ 2.5 GHz, I/Q wideband
2.5 GHz < f ≤ 6  GHz, I/Q wideband
20 % of carrier frequency
1 GHz
  using the integrated baseband source
with the R&S®SGT-K521 option
with the R&S®SGT-K521 and R&S®SGT-K522 options, 
with the R&S®SGT-K521, R&S®SGT-K522 and R&S®SGT-K523 options
60 MHz
120 MHz
160 MHz

240 MHz
Waveform length in one-sample steps 1 sample to 32 Msample
  with the R&S®SGT-K511 option 1 sample to 256 Msample
  with the R&S®SGT-K511 and R&S®GT-K512 options 1 sample to 1 Gsample
Waveform changeover time in multisegment waveform mode 50 MHz clock rate (external trigger, without clock change) 5 μs (meas.)
Sample resolution equivalent to D/A converter 16 bit
ACLR WCDMA 3GPP FDD, TM 1-64 > 68 dB; 71 dB (typ.)
EVM IEEE 802.11ac, 160 MHz, MCS 9 0.4 % (typ.)
Supported standards with R&S®WinIQSIM2™TM with additional options EUTRA/LTE, LTE-Advanced, 3GPP FDD incl. HSPA/HSPA+, GSM/EDGE/EDGE Evolution, TD-SCDMA, CDMA2000®/1xEV-DO, TETRA, IEEE 802.11a/b/g/n/p/ac, IEEE 802.16, Bluetooth®, NFC, DVB-H/DVB-T, DAB/T-DMB, GPS, Galileo, Glonass, BeiDou
Remote control   PCIe (single lane), Ethernet (TCP/IP) 10/100/1000BaseT, USB 2.0
General data
Power consumption   65 W (meas.)
Dimensions W × H × D, per unit 250 mm × 52.5 mm × 401 mm
(9.84 in × 2.07 in × 15.79 in)
1 HU, ½ 19“ rack width
Weight when fully equipped, per unit 4.0 kg (8.82 lb)
Recommended calibration interval 40 h/week operation in the full range of the specified environmental conditions 3 years

?